Feasibility of using 6 MV photon beams in contrast-enhanced radiotherapyстатья
Информация о цитировании статьи получена из
Scopus
Статья опубликована в журнале из списка Web of Science и/или Scopus
Дата последнего поиска статьи во внешних источниках: 16 марта 2022 г.
Аннотация:Contrast-enhanced radiotherapy (CERT) is a type of radiation therapy used to enhance the radiation dose absorbed by the tumor while sparing surrounding healthy tissues. The present study aims to assess feasibility of using 6 MV photons to increase radiation absorption in CERT. The dose absorbed by iodinated water was directly measured by ferrosulphate dosimetry. Concentrations of iodine (a dose-enhancing agent) ranged from 2.5 to 50 mg/ml. Solutions were exposed to 5 Gy radiation generated by the clinical linear accelerator SL75-5MT (Russia). The radiation dose applied did not account for increased absorbance due to the presence of iodine atoms. No reliable increase in the absorbed dose was observed for iodine concentrations ranging from 2.5 to 20 mg/ml. For 50 mg/ml concentrations the absorbed dose increased by 13% ± 5 % (p < 0.05). Normally, dose-enhancing concentrations observed in CERT studies range from 2.5 to 15 mg/ml, therefore, as demonstrated by our findings, employing 6 MV photon energy spectra in order to reach a therapeutically significant effect is unreasonable.